400 gpd Membrane Reverse Osmosis Commercial RO Membrane TFC-3012-400 GPD Element

Short Description:

This membrane is assembled with a high-quality Polyamide flat sheet. The TFC-3012-400 membrane has the capability to produce 400 gallons per day (GPD) and can remove up to 99% of total dissolved solids (TDS) such as chloride, lead, chromate, fluoride, and others. Designed with the industry-standard 3.0″x12″ size, this RO element fits most standard RO systems housing or cartridge.

These 3012 RO membrane models use the most advanced membrane film technology and manufacturing processes. This thin-film composite membrane (TFC) exhibits a salt removal rate of 97% at a pressure of 100 psi. As a manufacturer, we sell these membranes to both retailers and distributors (B2B) and end-users (B2C) around the world.


  • Brand Name: HID
  • Desalination: 97%
  • OEM/ODM: Accept
  • Manufacturer: Yes
  • Supply Ability: 20000pcs / day
  • Delivery Time: 2-7 days
  • Shipping Support: Express / Sea/ Land/ Air freight
  • Exceptional Services: Free samples
  • Place of Origin: Jiangsu, China
  • Price and Inquiries : Email: info@ro-hid.com
  • WhatsApp: +86-133-0528-4401
  • Model: TFC-3012-400G
  • Capacity: 400GPD
  • Product Detail

    APPLICATION

    Company Profile

    Product Tags

    How to order and get prices ?

    For prices and quotations, you can directly contact our sales team by leaving an Email: info@ro-hid.com, Phone: 0086-(0)511-81886899, WhatsApp: +8613305284401 or reach our customer service on Facebook messenger.

    What is the Salt Rejection percent for the TFC 3012-300 ?

    The Salt rejection for this membrane is set at 97%. This is the standard rejection rate for this TFC 3012- 400 gallons membrane, though the membrane may perform better than indicated.

    How much pressure is required for this membrane?

    The TFC 3012-400  GPD membrane requires 100 psi for optimal performance and durability. It can also withstand pressures of up to 300 psi, but this may impair the membrane's performance, life span, and structural damage.

    What is type of feed water is recommanded?

    Tapwater and underground water perform best with the membrane. Although some of our clients use it for other water sources, keep in mind that the rejection rate may drop to 95 or 96; otherwise, a higher pressure vessel is required (300 psi).

    Are you a Manufacturing company and do you customize products?

    The Salt rejection for this membrane is set at 97%. This is the standard rejection rate for a TFC 3012-400 gallons membrane, though the membrane may perform better than indicated.

    The TFC 3012 model is the most commonly used membrane in most standard small RO systems or home water purification machines. Capable of producing 300 gallons of clean fresh water per day with only 100 psi pressure. Because it is less expensive than other models in the 3012 series, it is ideal for home use, producing enough clean water at a low cost. To achieve the recommended percentage of RO water salts in your water, the membrane removes 97 percent of the salts solids in the water, leaving It with a pleasant taste and a low TDS level. The membrane performs best at 25°C, which is typically the temperature of most feed water.

    TFC 3012-400

    Package

    WeChat Image_20220420093619

    Small box

    - Quantities Per Box 25

    - Carton weight 5.8 kg

    50

    Big box

    - Quantities Per Box 50

    - Carton weight 11.6 kg

    HIDTM Commercial RO Membrane ranks the best brands in China among the RO membrane industry. RO Membrane Element has won the trust of numerous clients for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.

    HID ro membrane

    Membrane Dimensions:

    RO-Membrane-Dimension

     

    Model No. A (inch/mm) B (inch/mm) C (inch/mm) D (inch/mm) E (inch/mm)
    TFC-3012-200 298 20 16.8 67 257
    TFC-3012-300 298 20 16.8 72 257
    TFC-3012-400 298 20 16.8 72 257
    TFC-3013-400 330 19 16.8 68 300
    TFC-3012-500 298 20 16.8 72 257
    TFC-3213-600 330 19 16.8 76 300
    TFC-3213-800 330 19 16.8 78 300

    Commercial RO Membrane Model & Performance:

    Model No. Min. Salt Rejection (%) Stabilized Salt Rejection(%) Permeate Flow Rate(gpd) TestTemp. Test Pressure Test Water TDS
    TFC-3012-200 95 97 200 25℃ 65psi 500ppm
    TFC-3012-300 95 97 300 25℃ 65psi 500ppm
    TFC-3012-400 95 97 400 25℃ 80psi 500ppm
    TFC-3013-400 95 97 400 25℃ 100psi 500ppm
    TFC-3012-500 94 96 500 25℃ 100psi 500ppm
    TFC-3213-600 94 96 600 25℃ 100psi 500ppm
    TFC-3213-800 94 96 800 25℃ 100psi 500ppm

    1. Permeate flow rate and salt rejection is based on testing conditions: 25℃, PH 7.5, 20% recovery.
    2. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use, depending upon feedwater characteristics and operating conditions.

    Operating Limits

    Model No. Maximum 
    Operating Temperature
    Maximum 
    Operating  Pressure
    Feed Water PH Range,
     continuous operation
    Maximum Feed
    Water Turbidity
    Maximum 
    Feed Water SDI
    Chlorine 
    Tolerance
    TFC-3012-200 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3012-300 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3012-400 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3013-400 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3012-500 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3213-600 45℃ 200psi 4-11 1NTU 5 <0.1ppm
    TFC-3213-800 45℃ 200psi 4-11 1NTU 5 <0.1ppm

    Start-up Data of Model TFC-3013-400GPD

    400-GPD-Ro-Membrane-

    (test temp. 25℃; pressure at 65psi; TDS at 500ppm)

    400-GPD-Ro-Membrane-2-

    (test temp. 25℃; pressure at 65psi; TDS at 500ppm)


  • Previous:
  • Next:

  • HID RO Membranes are widely used in ultra-pure water, process pure water, cooling tower water, boiler water supply, pure water, throughout the electronics industry, optoelectronic industry, machinery manufacturing, fine chemical industry, medical pharmaceutical, food, and beverage industry, surface coating, and many other industries.