Yindlela elungileyo yokunyusa iimveliso zethu kunye nezisombululo kunye nokulungiswa. Umnqophiso wethu uhlala useka iimveliso zobugcisa kunye nezisombululo kubathengi abanobuchwephesha obugqwesileyo beSihluzo saManzi aseKhaya. Reverse Osmosis Membrane 3012 500G, Ukuze ufumane inkcazelo engakumbi, nceda uthumele i-imeyile kuthi. Sikhangela phambili ithuba lokukunceda.
Yindlela elungileyo yokunyusa iimveliso zethu kunye nezisombululo kunye nokulungiswa. Injongo yethu kukusoloko kuseka iimveliso zobugcisa kunye nezisombululo kubathengi abanobungcali obubalaseleyo Reverse Osmosis Membrane, I-RO Membrane, Sinabathengi abasuka kumazwe angaphezu kwama-20 kwaye isidima sethu samkelwa ngabathengi bethu ababekekileyo. Uphuculo olungapheliyo kunye nokuzabalazela ukunqongophala kwe-0% yimigaqo-nkqubo yethu emibini ephambili yomgangatho. Kufuneka ufune nantoni na, ungathandabuzi ukuqhagamshelana nathi.
ZIFIHLILETMIMembrane yoRhwebo ibeka ezona mpawu zibalaseleyo eTshayina phakathi kwe-RO inwebu ishishini.I-Membrane Filter Reverse Osmosis iphumelele intembeko yabathengi abaninzi ngokondla amanzi athembekileyo asulungekileyo kwiminyaka eyi-10. I-membrane nganye yenziwe nge-HID ephuhlisiwe kunye nephepha elihlolisiswe kwangaphambili kwaye lihamba ngeendlela ezingqongqo zokwenza kunye nokuhlolwa komgangatho wangaphakathi kunye novavanyo phambi kokunikezelwa. I-HID Membrane iye yaqinisekiswa yi-SGS & China Jiangsu Sanitation Bureau wrt amanzi okusela inwebu izinto.

| Umzekelo No. | Min. ItyuwaUkwaliwa (%) | Ityuwa ezinzileyoUkwaliwa(%) | Ukuqukuqela kokuPhumlaIreyithi(gpd) | TestTemp. | Uvavanyo loxinzelelo | Vavanya iTDS yamanzi |
| TFC-3012-200 | 95 | 97 | 200 | 25℃ | 65psi | 500ppm |
| TFC-3012-300 | 95 | 97 | 300 | 25℃ | 65psi | 500ppm |
| TFC-3012-400 | 95 | 97 | 400 | 25℃ | 80psi | 500ppm |
| TFC-3013-400 | 95 | 97 | 400 | 25℃ | 100psi | 500ppm |
| TFC-3012-500 | 94 | 96 | 500 | 25℃ | 100psi | 500ppm |
| TFC-3213-600 | 94 | 96 | 600 | 25℃ | 100psi | 500ppm |
| TFC-3213-800 | 94 | 96 | 800 | 25℃ | 100psi | 500ppm |
1. Isantya sokuhamba kwePermeate kunye nokugatywa kwetyuwa kusekelwe kwiimeko zokuvavanya: 25℃, PH 7.5, 20% yokubuyisela.
2. Ukugatywa kwetyuwa okuzinzile ngokuqhelekileyo kufezekiswa kwiiyure ezingama-24-48 zokusetyenziswa rhoqo, ngokuxhomekeke kwiimpawu zamanzi okutya kunye neemeko zokusebenza.
| Umzekelo No. | Ubuninzi Ubushushu bokusebenza | Ubuninzi Uxinzelelo lokuSebenza | Yondla Amanzi Uluhlu lwePH, ukusebenza okuqhubekayo | Ubuninzi Bokutya UGuquguquko lwaManzi | Ubuninzi Yondla Amanzi SDI | I-Chlorine Ukunyamezelana |
| TFC-3012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3012-300 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3012-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3013-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3012-500 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3213-600 | 45℃ | 200psi | 4-11 | 1NTU | 5 | |
| TFC-3213-800 | 45℃ | 200psi | 4-11 | 1NTU | 5 |
I-HID RO Membranes isetyenziswa kakhulu kumanzi acocekileyo, inkqubo yamanzi acocekileyo, amanzi enqaba yokupholisa, unikezelo lwamanzi kwibhoyila, amanzi acocekileyo, kulo lonke ishishini lombane, ishishini le-optoelectronic, ukuveliswa koomatshini, ishishini lemichiza elungileyo, amayeza ezonyango, ukutya, kunye neshishini lokusela, ukugquma komhlaba, kunye namanye amashishini amaninzi.